Software icd.control

SOFTWARE: icd.control

SOFTWARE FOR CONDUCTED IMMUNITY FROM DC TO 1GHZ

icd.control - The highlights

icd.control is the dedicated software for all conducted immunity testing using AMETEK CTS generators. Adopted to the generator to be controlled it offers intuitive still sophisticated set-up and user guidance, allowing fast and reliable testing, easy and convenient.
An extensive library of standards, a number of pre-programmed drivers to control external measuring devices and a high-sophisticated reporting tool are just a few highlights.

The current version icd.control 6.1.2 offers:

  • Windows 7, Windows 8 and Windows 10 compatibility
  • Support of USB, RS232 and GPIB interfaces
  • Library of the latest international standards, as well as manufacturer
    requirements for automotive conducted immunity testing
  • Enhanced and highly flexible reporting capabilites
  • Control of external measuring and data logger instruments
  • Power calibration capability as proposed in the actual IEC 61000-4-6 Ed.4 and used by a number of test labs
  • Up-to-date design and navigation
  • Intuitive operation

Top

The standards update

New standards implemented in the 6.1.x release:

  • Karma C1800STA0130 (Revision 2, 2010-05)
  • IEC 60669-2-1 (Edition 4.2, 2015-03)
  • IEC 61204-3 (Edition 3, 2016-10)
  • EN 61326-2-4 (Edition 2, 2012-07)
  • CAT EC42 (Version 4, 2015-05)
  • CTCT EMC-1 (Revision 1, 2016-04)
  • Nissan 28401NDS02 [8] (2016-03)
  • ISO TS 7637-4 (2017-03)

New standards implemented in the 6.0.x release:

  • EN 50579 (2012-01)
  • IEC 61000-4-16 (Edition 2, 2015-12)
  • DIN EN 61000-4-6 (2014-08)
  • DIN EN 61000-4-16 (2016-10)
  • DIN EN 61000-4-19 (2015-03)
  • IEC 61000-4-16 (Edition 2, 2015-12)
  • DIN EN 61000-6-1 (2016-05)
  • DIN EN 61000-6-2 (2016-05)
  • DIN EN 61000-6-7 (2015-12)
  • IEC 61000-6-1 (Edition 3, 2016-08)
  • IEC 61000-6-2 (Edition 3, 2016-08)
  • DIN EN 60601-1-2 (2016-05)
  • DIN EN 60601-2-25 (2016-08)
  • IEC 60601-1-2 (Edition 3, 2007-03)
  • IEC 60601-1-2 (Edition 4, 2014-02)
  • IEC 60601-2-25 (Edition 2, 2011-10)
  • CLC-TR 50579 (2012-08)
  • DIN EN 12016 (2013-12)
  • EN 55024 (2009-06)
  • EN 55024 (2016-01)
  • DIN EN 60255-26 (2014-03)
  • DIN EN 62020 (2005-11)
  • DIN EN 62132-4 (2006-10)
  • IEC 61326-3-2 (Edition 1, 2008-01)
  • IEC 61850-3 (Edition 2, 2013-02)
  • IEC 62132-4 (Edition 1, 2006-02)

New Manufacturer Standards in the 6.0.x release:

  • BSH EMV-AB (2016-04)
  • DNBVGL-CG-0339 (2015-11)
  • IEC 60533 (Edition 3, 2015-08)
  • Lloyd's Register Type Approval System (2013)
  • MIL-STD-461G (2015-12)
  • Defense Standard 59-411 - Part 3 (2014-03)
  • Boeing D6-16050-4 (Issue D, 2002-06)
  • Boeing D6-16050-5 (Issue C, 2006-09)
  • BMW GS 95002 (2012-09)
  • Case New Holland ENS0310 (Revision K, 2013-12)
  • Fiat CS.00054 (2015-01)
  • Ford FMC1278 (Revision 2, 2016-10)
  • General Motors GMW 3097 (2015-06)
  • Hyundai-Kia ES96200-00 (Revision L, 2014-03)
  • Hyundai-Kia ES96200-00 (Revision O, 2016-03)
  • ISO 11451-4 (Edition 3, 2013-03)
  • ISO 11452-7 (Edition 2, 2003-11)
  • ISO 11452-8 (Edition 2, 2015-06)
  • Jaguar JLR-EMC-CS (Version 1, 2015-02)
  • John Deere JDQ 203 (2013-02)
  • McLaren MSL03040063 (2013-04)
  • Mercedes-Benz MBN 10 284-2 (2015-07)
  • Nissan 28401 NDS02 [6] (2013-01)
  • Nissan 28401 NDS02 [7] (2014-09)
  • PSA B21 7110 (Revision E, 2015-09)
  • SsangYong SES-E-922 (Issue 5, 2013-10)
  • Tesla TS-0000048-03 (2013-05)
  • Volkswagen VW TL 81000 (2016-02)
  • Volkswagen VW TL 82531-3 (2012-06)
  • Volvo REQ-043878 (Revision 2, 2014-02)
  • Volvo STD 1579908 (Issue 4, 2003-11)
  • Volvo STD 31850329 (Revision 4, 2014-06)
  • and more

New standards implemented in the 5.3.x release:

  • IEC 61000-4-6 Ed.4 (2013-10)
  • EN 50579 (2012-01)
  • ISO 11451-4 (2006)
  • BMW - GS 95002-2 (2013-07)
  • BMW - GS95025-1 (2012-05)
  • EN 12016 (2004-04)
  • DIN EN 60945 (2003-07)
  • IEC 60255-26 (Edition 3, 2013-05)
  • IEC 60947-2 (Edition 4.1, 2009-05)
  • IEC 61000-4-19
  • IEC 61000-6-7
  • IEC 61204-3 (Edition 2, 2011-06)
  • Fiat - 9-90111-01 (2012-06)
  • Germanischer Lloyd SE - VI-7-2 Prüfanforderungen (2012)
  • Jaguar - EMC-CS-2010JLR (Version 1.2, 2012-06)
  • Lloyd's Register Type Approval System (2002)
  • Nissan - 28401 NDS 02 (Rev.5, 2010-12
  • Proton - PES-6022 (2010-10)
  • PSA - B21 7110 D (2012-07)
  • Renault - 36-00-808-M (2012-07)
  • Telcordia GR-1089-CORE (Issue 6, 2011-05)
  • Volkswagen - TL 81000 (2013-02)
  • DO 160F - Sections 16 and 18
  • Defence Standard 59-411 Part 3 - DRS01
  • and more

Pre-programmed Standard Test routines for fast and reliable testing

icd.control Standard generatorZoom
icd.control offers numerous Standard Test routines for various applications. With only a few steps a test is set up. Using Standard Test routines allows fast and reliable testing.
Still these Standard Test routines can be modified and saved as user specific test routines in order to adopt special requirements which go beyond the basic request without having to program such test routines from scratch. User specific test routines are composed easy, fast and efficient.

Top

User Test routines - Programmed in vectors

icd.control Vector testZoom
Some test requirements may be too complex to be programmed in the common way. For such needs icd.control offers the vector programming mode. A test sequence can be specified with different vectors, each consisting of a start frequency/level and a stop frequency/level set of parameters. Even most complex requirements are easily set up and tested in the Vector mode.

Top

Implementation of external measuring instruments

External measuring equipmentZoom
External measuring equipment, e.g. Power Meter, Oscilloscope, Spectrum Analyser) can easily be implemented in the set-up for either measuring the injected rf test signal or for EUT monitoring during test. The data logger can handle almost every kind of measuring equipment having a GPIB interface.
Up to four single channel instruments or any corresponding number of multi-channel equipment can be logged, each channel being individually controlled. Feedback signals from external instruments can be used as interrupts to control the test procedure.

Top

Enhanced reporting capability

icd.control reportingZoom
icd.control offers an enhanced reporting capability. The complete test data including any comments entered in case of fail events is given in details. Graphics and data of the levelling, impedance characteristic and the recorded data from the used external measuring equipment can be included. Graphic information about the test set-up can be added for better documentation of the performed test.
Test reports are automatically transfered into Rich-Text-Format (rtf) and can thus be easily post-processed by any software recognising rtf format (e.g Microsoft Word).

Top

Enhanced calibration capability

icd.control calibration Zoom
icd.control offers various calibration modes in order to perform the levelling of the test set-up. The step width can be set to the minimum possible step width of the controlled CWS 500 model. Special requirements such as specified in the IEC 60601-1-2 standard for medical equipment (only positive level tolerance allowed) can be covered.

Calibration data stored in the calibration mode can be downloaded into the CWS 500 or uploaded from the CWS 500.